| Sign In | Join Free | My insurersguide.com |
|



| Performance Parameters: | |||||
| Measurement Range | Gauge(G) | 10KPa,20KPa,35KPa,100KPa,200KPa,350KPa,1000KPa,2000KPa | |||
| Absolute(A) | 100KPaA,200KPaA,350KPaA,700KPaA,1000KPaA,2000KPaA | ||||
| Sealed(S) | 3500KPaS,7MPaS,10MPaS | ||||
| Typ | Max | Unit | |||
| NonLinearity | ±0.15 | ±0.3 | %F.S | ||
| Repeatability | 0.05 | 0.1 | %F.S | ||
| Hysteresis | 0.05 | 0.1 | %F.S | ||
| Zero Offset Output | 0±1 | 0±2 | mV | ||
| Full Scale Output | ≤20KPa | 50±1 | 50±2 | mV | |
| ≥35kPa | 100±1 | 100±2 | mV | ||
| Zero Offset Temp. Drift | ≤20KPa | ±1 | ±2.5 | %F.S | |
| ≥35kPa | ±0.8 | ±1.5 | %F.S | ||
| Full Scale Temp. Drift | ≤20KPa | ±1 | ±2 | %F.S | |
| ≥35kPa | ±0.8 | ±1.5 | %F.S | ||
| Compensated Temp. | ≤20KPa | 0~50 | ºC | ||
| ≥35kPa | 0~70 | ºC | |||
| Operating Temperature | -20~80 | ºC | |||
| Storage Temperature | -40~125 | ºC | |||
| Allowable Overload | 3 times the full scale | ||||
| Burst Pressure | 5X the full scale | ||||
| Long-term Stability | 0.2 % | F.S/Year | |||
| Diaphragm Material | 316L | ||||
| Insulation Resistance | ≥200MΩ 100VDC | ||||
| Vibration | No change under conditions of 10gRMS, 20Hz to 2000Hz | ||||
| Shock | 100g,11ms | ||||
| Response Time | ≤1ms | ||||
| O-ring Seal | Nitrile rubber or Fluoro rubber | ||||
| Filling Medium | Silicon Oil | ||||
| Weight | ~25g | ||||
| The parameters are tested under the following conditions: Constant voltage of 10V and ambient temperature of 25ºC | |||||
| Outline Construction | |
| Pressure Tube <3.5MPaS | ![]() |
| Normal ≥3.5MPaS <40MPaS | ![]() |
| Electrical connection and compensation |
![]() |
| Selection Examples |

|
|
HT26V Pressure Sensor Core with 10VDC Power Supply Silicon Piezoresistive and 316L Isolation Diaphragm Images |